System/3
Series:
These
are computer based, software driven clinical units.
Our software provides intuitive instrument interface,
is easy to use and offers access to powerful features
for clinical work and research grade data collection.
More details are available. Send E-mail
for a free demonstration disk which provides a
product overview and a software features summary,
as well as an example of a session with a patient.
|
 |
Units
|
Description |
Functional
Specification
|
| Biofeedback
System/3 |
Six
Channel Computer Based System:
It provides:
Two sEMG
Two Skin Temperature
One Respiration
One SCL
One SCR |
Major
Software Features:
Patient Database
Automatic Data Storing
Detailed or Summary Data
Automated Protocols
Report Writing
Patient Progress/Treatment Summaries
Reports on Color Printers
Feedback:
Graphic Computer Screen, User defined, Built-in
Speakers, External Audio Triggers
Range:
0.01 to 1000 uV,
Band Width:
25-425 Hz.
Temp.:
60-100 F, Resolution 1/400 F
Resp.: Belt Attached, Pressure Sensitive
Force Transducer
SCL&SCR: 0.8 - 50 uS/cm2
Controls: Base Line, Audio Above/Below,
Visual Range, Screen Time, Averaging, Detailed/Summary
Data, Trigger Outputs, Stim Unit Controls
Sensor SEMG: Active Electrodes
Temp.:
High Accuracy Thermister
Resp.: Pressure Transducer
SCL&SCR: Gold Plated 2.5cm2 conductors |
| NeuroSys/3-4 |
Four
Channel Electromyography |
Major
Software Features:
Patient Database
Automatic Data Storing
Detailed or Summary Data
Automated Protocols
Report Writing
Patient Progress/Treatment Summaries
Reports on Color Printers
Feedback: Graphic Computer Screen,
User defined, Built-in Speakers, External Audio
Triggers
Range:
sEMG: 0.01 to 1000 uV, Band Width: 25 - 425 Hz.
Controls: Base Line, Audio Above/Below,
Visual Range, Screen Time, Averaging, Detailed/Summary
Data, Trigger Outputs, Stim Unit Controls
Sensors:
sEMG: Active Electrode |
| NeuroSys/3-8 |
Eight
Channel of sEMG |
Same
as NeuroMuscular system/3 but with eight channel
of sEMG |
| Rehabilitation
System/3 |
Eight
Channel Computer Based System:
It provides:
Four sEMG
Two Skin Temperature
One Respiration
One SCL
One SCR |
Major
Software Features:
Patient Database
Automatic Data Storing
Detailed or Summary Data
Automated Protocols
Report Writing
Patient Progress/Treatment Summaries
Reports on Color Printers
Feedback: Graphic Computer Screen,
User defined, Built-in Speakers, External Audio
Triggers
Range:
0.01 to 1000 uV, Band Width: 25
- 425 Hz.
Temp.: 60-100 F, Resolution 1/400
F
Resp.: Belt Attached, Pressure
Sensitive Force Transducer
SCL&SCR: 0.8 - 50 uS/cm2
Controls: Base Line, Audio Above/Below,
Visual Range, Screen Time, Averaging, Detailed/Summary
Data, Trigger Outputs, Stim Unit Controls
Sensors:
sEMG: Active Electrode
Temp.: High Accuracy Thermister
Resp.: Pressure Transducer
SCL&SCR: Gold Plated 2.5cm2
conductors |
| MEDAC
System/3 |
Eight
Channel Computer Based System
It provides:
Two sEMG.
Two Skin 3. Temperature.
One Respiration.
One SCL.
One SCR.
Photo Plethysomography for Heart Rate, Interbeat
Interval, Blood Volume Pulse.
Computerized Stress Assessment for Researchers.
Brief Physiological Stress Profile.
Computerized Headache Check List. |
Major Software Features:
Patient Database
Automatic Data Storing
Detailed or Summary Data
Automated Protocols
Report Writing
Patient Progress/Treatment Summaries
Reports on Color Printers
Feedback: Graphic Computer Screen,
User defined, Built-in Speakers, External Audio
Triggers
Range:
sEMG: 0.01 to 1000 uV, Band Width:
25 - 425 Hz.
Temp.: 60-100 F, Resolution 1/400
F
Resp.: Belt Attached, Pressure
Sensitive Force Transducer
SCL&SCR: 0.8 - 50 uS/cm2
Controls: Base Line, Audio Above/Below,
Visual Range, Screen Time, Averaging, Detailed/Summary
Data, Trigger Outputs, Stim Unit Controls
Sensors:
sEMG: Active Electrode
Temp.: High Accuracy Thermister
Resp.: Pressure Transducer
SCL&SCR: Gold Plated 2.5cm2
conductors
PPG: 880nm, radiant power compensated
for ambient illumination, 3mW max. Dynamic Range
> 90dB |
| MEDAC
System/3R |
Same
as MEDAC System/3 above, but with four channels
sEMG, instead of two channels sEMG. |
As
above. |
|
Rental
& Lease Terms:
Rental of units is arranged on an
"as available" basis with a minimum of two months
for length of rental. Lease payments are based on
three year term and 10% buy out at the end of the term.
|
 |
We
now offer several different types of Disposable
Electrodes for sEMG and Electrical Stimulation
devices.
All
Disposable Electrode
Orders Are Shipped
Within 48 hours! |
|
|
|
|