System/3 Series:

These are computer based, software driven clinical units. Our software  provides intuitive instrument interface, is easy to use and offers access to powerful features for clinical work and research grade data collection. More details are available. Send E-mail for a free demonstration disk which provides a product overview and a software features summary, as well as an example of a session with a patient. 
Units
Description Functional Specification
Biofeedback System/3™ Six Channel Computer Based System:
It provides:
Two sEMG
Two Skin Temperature
One Respiration
One SCL
One SCR
Major Software Features:
Patient Database
Automatic Data Storing
Detailed or Summary Data
Automated Protocols
Report Writing
Patient Progress/Treatment Summaries
Reports on Color Printers
Feedback:
Graphic Computer Screen, User defined, Built-in Speakers, External Audio Triggers
Range:
0.01 to 1000 uV,
Band Width:
25-425 Hz.
Temp.: 60-100 F, Resolution 1/400 F
Resp.: Belt Attached, Pressure Sensitive Force Transducer
SCL&SCR: 0.8 - 50 uS/cm2

Controls: Base Line, Audio Above/Below, Visual Range, Screen Time, Averaging, Detailed/Summary Data, Trigger Outputs, Stim Unit Controls
Sensor SEMG: Active Electrodes

Temp.: High Accuracy Thermister
Resp.: Pressure Transducer
SCL&SCR: Gold Plated 2.5cm2 conductors
NeuroSys/3™-4 Four Channel Electromyography Major Software Features:
Patient Database
Automatic Data Storing
Detailed or Summary Data
Automated Protocols
Report Writing
Patient Progress/Treatment Summaries
Reports on Color Printers
Feedback: Graphic Computer Screen, User defined, Built-in Speakers, External Audio Triggers
Range:
sEMG: 0.01 to 1000 uV, Band Width: 25 - 425 Hz.
Controls: Base Line, Audio Above/Below, Visual Range, Screen Time, Averaging, Detailed/Summary Data, Trigger Outputs, Stim Unit Controls
Sensors:
sEMG: Active Electrode
NeuroSys/3™-8 Eight Channel of sEMG Same as NeuroMuscular system/3 but with eight channel of sEMG
Rehabilitation System/3 Eight Channel Computer Based System:
It provides:
Four sEMG
Two Skin Temperature
One Respiration
One SCL
One SCR
Major Software Features:
Patient Database
Automatic Data Storing
Detailed or Summary Data
Automated Protocols
Report Writing
Patient Progress/Treatment Summaries
Reports on Color Printers
Feedback: Graphic Computer Screen, User defined, Built-in Speakers, External Audio Triggers
Range:
0.01 to 1000 uV, Band Width: 25 - 425 Hz.
Temp.: 60-100 F, Resolution 1/400 F
Resp.: Belt Attached, Pressure Sensitive Force Transducer
SCL&SCR: 0.8 - 50 uS/cm2
Controls: Base Line, Audio Above/Below, Visual Range, Screen Time, Averaging, Detailed/Summary Data, Trigger Outputs, Stim Unit Controls
Sensors:
sEMG: Active Electrode
Temp.: High Accuracy Thermister
Resp.: Pressure Transducer
SCL&SCR: Gold Plated 2.5cm2 conductors
MEDAC System/3™ Eight Channel Computer Based System
It provides:
Two sEMG.
Two Skin 3. Temperature.
One Respiration.
One SCL.
One SCR.
Photo Plethysomography for Heart Rate, Interbeat Interval, Blood Volume Pulse.
Computerized Stress Assessment for Researchers.
Brief Physiological Stress Profile.
Computerized Headache Check List.
Major Software Features:
Patient Database
Automatic Data Storing
Detailed or Summary Data
Automated Protocols
Report Writing
Patient Progress/Treatment Summaries
Reports on Color Printers
Feedback: Graphic Computer Screen, User defined, Built-in Speakers, External Audio Triggers
Range:
sEMG: 0.01 to 1000 uV, Band Width: 25 - 425 Hz.
Temp.: 60-100 F, Resolution 1/400 F
Resp.: Belt Attached, Pressure Sensitive Force Transducer
SCL&SCR: 0.8 - 50 uS/cm2
Controls: Base Line, Audio Above/Below, Visual Range, Screen Time, Averaging, Detailed/Summary Data, Trigger Outputs, Stim Unit Controls
Sensors:
sEMG: Active Electrode
Temp.: High Accuracy Thermister
Resp.: Pressure Transducer
SCL&SCR: Gold Plated 2.5cm2 conductors
PPG: 880nm, radiant power compensated for ambient illumination, 3mW max. Dynamic Range > 90dB
MEDAC System/3R™ Same as MEDAC System/3 above, but with four channels sEMG, instead of two channels sEMG. As above.

Rental & Lease Terms:

Rental of units is arranged on an "as available" basis with a minimum of two months for length of rental.  Lease payments are based on three year term and 10% buy out at the end of the term.

 We now offer several different types of  Disposable Electrodes for sEMG and Electrical Stimulation devices.

All Disposable Electrode Orders Are Shipped Within 48 hours!


About | Contact | Privacy Policy | Terms of Use | Site Requirements
© 2002 NeuroDyne Medical Corp. All rights reserved